If CPU temperature reaches 57 degrees, fan duty will be at 60%.ģ.
Sample Desc: Assuming the above Open Loop Fan Table is for CPU temperature sensor, when the CPU temperature reaches between 20~25 degrees, the fan duty will be at 30%. Login to IPMI webUI > Settings > FAN SettingsĢ.Ĝhose Open Loop Control Table, then set your customize fan table and save. If by remote -> ipmitool -H -U admin -P admin raw 0x3a 0x06 0x01 0x00 BIOS/BMC FW mass update via Asrrmgmttoolġ. If by win OS local -> ipmitool -I ms raw 0x3a 0x06 0x01 0x00 If by local -> ipmitool raw 0x3a 0x06 0x01 0x00 Ipmitool raw 0x3a 0x06 0x01(Fan duty) 0x00(flag) I.ěIOS SETUP(mostly for BMC AST2400 series)īIOS SETUP screen→Advanced→H/W Monitor→ or
IPMITOOL command (for barebone/system)Īttn: We DO NOT RECOMMEND that user adjust the fan table due to the system has been fine-tuned from the ASRockRack thermal team. IPMI webUI (mostly for BMC AST2500 series) BIOS SETUP (mostly for BMC AST2400 series) And check to whether the BIOS update process is success or fail.Ĭheck to the latest BIOS version of the host machine.Įnvironment: Windows/Linux/DOS mode Tool: ipmitool (search & download from Internet) Interface:
(Supports server motherboard built with BMC AST2500 controller) Preparationġ.ĝownload and install the Server Management Utility.ġ~3: Key-in the IP address range to search out the host machine where need to do the BIOS update procedure.Ĥ~5: Key-in BMC login account, then pull-down to check those searched machines.
How to update BIOS through Server Management Utility? It doesn't have an eBPF problem.ĮBPF is fixed upstream already. Variant 1 (CVE-2017-5753/) Bounds Check Bypass unless you run 4.9 or later. Linux patches info is in below website for variant 2 and 3.
If you are using priority Linux, and need to patch by yourself. Some Linux distributions have more than one update.įor example: CVE-2017-5753 and CVE-2017-5715 is for “Spectre”, CVE-2017-5754 is for “Meltdown”
Will ASRock Rack release the FW for it?ĪSRock Rack has been notified about an industry-wide potential security issue and is taking action to help our customers address their concerns.
Malicious code using this method and running locally on a normally operating platform could infer data values from memory. The issue is a new side-channel analysis method developed by external researchers that gathers information by observing the physical behavior of certain processing techniques that are common to modern computing platforms, when operating as designed.
Steps to Console Redirection Setting via Serial (COM) Port eboot server system and SOL has start working.Please follow the Java SOL setting, and click.NOTE: A compatible JRE must be installed in the system prior to the launch of the JNLP file. Megarac SP setting (client side): Remote Control→Java SOL.Please follow the BIOS setting for the server side: Advanced→Serial Port Console Redirection→.Make sure RJ45 port plug into IPMI_LAN port on the server side board, the RJ45 port plug into general LAN port on client side.